Introduction
Device description
Installation and operation
Technical specifications
Approvals
1
2
3
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RTLS

  • Page 1 Introduction Device description Installation and operation SIMATIC RTLS Technical specifications Localization systems SIMATIC RTLS5201T Approvals Operating Instructions 08/2023 C79000-G8976-C687-02...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................5 Device description ..........................9 Characteristics ........................9 Order data for RTLS5201T and accessories................9 Transponder identification....................10 Dimension drawing......................10 Installation and operation ........................11 Notes on installation ......................11 Operation .......................... 14 Cleaning and maintenance....................22 Technical specifications ........................
  • Page 4 Table of contents SIMATIC RTLS5201T Operating Instructions, 08/2023, C79000-G8976-C687-02...
  • Page 5: Introduction

    These operating instructions apply to the following transponder: • RTLS5201T (Article number: 6GT2752-0TS01) Further documentation You can find the complete documentation for all SIMATIC RTLS products at the following address: Link: (https://support.industry.siemens.com/cs/us/en/ps/25277/man) Trademarks The following and possibly other names not identified by the registered trademark sign ®...
  • Page 6 Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats. To ensure that you are always informed about product updates, subscribe to the Siemens Industrial Security RSS feed at: https://www.siemens.com/cert (https://www.siemens.com/cert)
  • Page 7 Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations.
  • Page 8 Introduction SIMATIC RTLS5201T Operating Instructions, 08/2023, C79000-G8976-C687-02...
  • Page 9: Device Description

    Device description Characteristics SIMATIC RTLS5201T Characteristics ① Design Ribbed surface for unlocking the battery compart‐ ment cover ② Battery compartment (press ribbed surface and open battery compartment cover to the front) General The transponder is the mobile device for localization in the RTLS localization system.
  • Page 10: Transponder Identification

    Device description 2.4 Dimension drawing Transponder identification The following unique identifiers are printed on the enclosure of the transponder for identification: Identifier Example Description 6GTxxx-xxxx Specifies the article number of the transponder. VPJM123456 Specifies the serial number of the transponder. Addr 1:22:33:44 Specifies the radio address of the transponder in the Locat‐...
  • Page 11: Installation And Operation

    Installation and operation Notes on installation Note Before you install the transponders, read this section carefully to ensure problem-free installation and commissioning. The transponders can only be used in conjunction with the RTLS localization system. You can obtain the radio address of the RTLS5201T via the data matrix code printed on the transponder or via the identifier "Addr".
  • Page 12 When electromagnetic fields are reflected or there are other radio sources, this will result in interferences. These circumstances will result in incorrect measurements; however, these can be largely detected and corrected with the appropriate software (e.g. SIMATIC RTLS Locating Manager). We still recommend that you prevent these influences. Especially objects that cannot be penetrated by radio waves can cause localization errors.
  • Page 13 The transponder must be attached in such a way that the Siemens lettering of the battery cover points upwards. Antenna 2 is configured when the transponder is attached to a horizontal surface. Misconfiguration can lead to a reduction of the range.
  • Page 14: Operation

    Installation and operation 3.2 Operation Operation Battery life The battery life of the batteries used in the transponder depends on various factors and settings. Note To achieve optimal battery life, you must make appropriate adjustments to the delivery state since it was designed to allow fast commissioning. Factors that reduce the battery life: •...
  • Page 15 Installation and operation 3.2 Operation Mixed operation of the transponders/gateways of the RTLS4000 product family and transponders of the RTLS5000 product family The SIMATIC RTLS5201T transponder is compatible with the transponders and gateways of the RTLS4000 product family. Unlike the transponders of the RTLS4000 product family, it exclusively uses the UWB channel 5 for localization and communication.
  • Page 16 Installation and operation 3.2 Operation Step 1: Adapt transponders of the RTLS4000 product family • In the "Localization configuration" client, change UWB channel 2 to UWB channel 5. • Change the "PRF" parameter (parameter name and parameter value) as follows: – PRF: DW_PRF = DW_enePRF_64_MHz –...
  • Page 17 Installation and operation 3.2 Operation Step 2: Adapt gateways of the RTLS4000 product family (2 possible variants) Variant 1 (recommended): The functions of the radio interfaces "IF2" and "IF4" are swapped. Advantages: No reconfiguration of the UWB channels, preambles and PRF is required and the optimum antenna configuration of the gateways is retained.
  • Page 18 Installation and operation 3.2 Operation • Check in the "Localization Configuration" client whether the "CCP" and "Data Sending Period" parameters are configured the same on both interfaces (green frame, blue frame). • Restart the gateway via the "Reset" button (red frame). Variant 2: The functions of the radio interfaces are retained, but the radio parameters are changed to match the transponders.
  • Page 19 Installation and operation 3.2 Operation • Red frame: Set the UWB channel for interface 4 (IF4) to channel 5 and then click the "Set" button. • Green frame: For the "IF2_DW_PRF" parameter, enter the value "DW_enePRF_16Mhz" and then click the "Set" button. •...
  • Page 20 Installation and operation 3.2 Operation Step 3: Adapt transponder of the RTLS5000 product family • Download the firmware "MARS V1.0": (https://support.industry.siemens.com/cs/us/en/ps/ 25277/dl) • Add the cagl file in the RTLS subdirectory "...\Server\Firmware". SIMATIC RTLS5201T Operating Instructions, 08/2023, C79000-G8976-C687-02...
  • Page 21 Installation and operation 3.2 Operation Step 4: Commission transponder of the RTLS5000 product family • Insert a battery into the RTLS5201T transponder, since it is shipped without a battery. • In the "Network configuration" client, check whether the transponder is in the default group and whether the valid firmware is present.
  • Page 22: Cleaning And Maintenance

    Improper opening or repair of the transponder may result in serious risks for the user. Opening the transponder without permission renders the warranty of the Siemens AG null and void. Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products.
  • Page 23: Technical Specifications

    Technical specifications RTLS5201T technical specifications Table 4-1 Technical specifications of the RTLS5201T transponder   6GT2752-0TS01 Product name SIMATIC RTLS5201T     PULSE wireless frequencies (communication and localiza‐   tion) Wireless method IEEE 802.15.4-2015 UWB HRP PHY Supported localization technologies • • TDOA Transmission speed 850 Kbps...
  • Page 24: Technical Specifications Of The Battery

    Technical specifications 4.2 Technical specifications of the battery Technical specifications of the battery Table 4-2 Technical specifications of the battery   6GT2792-0BB41 Product name Battery for RTLS5201T Brand: SAFT LS14250 Supply voltage 3.6 V Capacity 1200 mAh Cell type Lithium battery Permitted ambient temperature  ...
  • Page 25: Approvals

    Approvals Country-specific approvals All the latest radio approvals for RTLS devices are available on the Internet (https:// cache.industry.siemens.com/dl/files/340/109784340/att_1082212/v1/SIMATIC-RTLS- Approvals.pdf). If a device has one of the following marks, the corresponding approval has been obtained. Labeling Description Australia/New Zealand South Africa (ICASA)
  • Page 26 ANATEL: XXXXYYZZZZ tel.gov.br). Importer UK: Siemens plc, Sir William Siemens House, Princess Road, Manchester M20 Mexico (NOM) La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia per‐...
  • Page 27 You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/en/en/view/109801531). The SIMATIC RTLS products described in this document meet the requirements of the following directives/regulation: • Radio Equipment Regulations: SI 2017/1206 Radio Equipment Regulations 2017, and related amendments •...
  • Page 28 Approvals Article 3 (1) a) Protection of health and safety • EN 62368-1 Equipment for audio/video, information and communication technology – Part 1: Safety requirements • EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions in electromagnetic fields (0 Hz - 300 GHz) The products described in these operating instructions meet the requirements of EU directive 2014/30/EU "Electromagnetic Compatibility"...
  • Page 29 Approvals FCC information Siemens SIMATIC RTLS5201T (MLFB 6GT2752-0TS01); FCC ID: SCF5201T01 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 30 Approvals (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Radiation exposure statement (RSS-102) This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 5 mm between the radiator and your body.