● Interface Name
Shows the name of the interface.
● MAC Address
Shows the MAC address.
● IP Address
Shows the IPv4 address of the subnet.
● Subnet Mask
Shows the subnet mask.
● Address Type
Shows the address type. The following values are possible:
– Primary
– Secondary
● IP Assignment Method
Shows how the IPv4 address is assigned. The following values are possible:
– Static
– Dynamic (DHCP)
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
The first IPv4 address that was configured on the IPv4 interface.
All other IPv4 addresses that were configured on the IPv4 interface.
The IPv4 address is static. You enter the settings in "IP Address" and "Subnet Mask".
The device obtains a dynamic IPv4 address from a DHCPv4 server.