LUNA2000-(5-30)-S0
User Manual
Figure 3-6 Battery control parameter setting
Table 3-4 Time-of-use parameter setting
Parameter
Charge from grid
Grid charge cutoff
SOC
Fully Fed to Grid
Issue 01 (2020-09-18)
Description
If Charge from grid function is disabled by
default, comply with the grid charge requirements
stipulated in local laws and regulations when this
function is enabled.
Set the grid charge cutoff state of charge (SOC).
This mode applies to the grid-tied scenario where PV energy is fully fed to the grid.
This mode maximizes the PV energy for grid connection. When the generated PV energy
in the daytime is greater than the maximum output capability of the inverter, the batteries
are charged to store energy. When the PV energy is less than the maximum output
capability of the inverter, batteries discharge to maximize the output energy of the
inverter to the grid.
Copyright © Huawei Technologies Co., Ltd.
3 Application Scenarios and Settings
Value Range
Disable
Enable
[0, 100%]