Download Print this page
Sealey TP200.V3 Instructions

Sealey TP200.V3 Instructions

Air operated fuel drainer

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT:
BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS,
WARNINGS AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
Petrol is a highly flammable liquid and any spillage will evaporate to form a flammable, heavier than air vapour which is easily ignited.
Common ignition sources include, but are not limited to, smoking and lit matches, welding and cutting equipment, heaters, all types of
electrical equipment unless specifically designed as suitable for use in flammable atmosphere. Even low voltage inspection lamps, if
damaged, can ignite petrol vapour
Please take time to read the following safety information before commencing work with the TP200.V3.
Use the drainer only for its intended purpose.
Familiarise yourself with the applications, limitations, and potential hazards of this product.
Use original Sealey spare parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
We recommend that this unit is used outdoors or in a well ventilated area, and well away from pits or other openings in the ground
where vapour can collect.
Disconnect the vehicle's battery before draining fuel.
Keep a foam or dry powder fire extinguisher nearby.
Ensure containers cannot easily be knocked over during filling.
Ensure the drainer tank is large enough to hold the contents of the fuel tank you are draining.
Ensure space required for use and maintenance of the drainer is adequate, free from unrelated
materials and has good lighting.
Attach earth lead to the fuel container using the crocodile clip supplied.
Always use the earth bonding straps by connecting one to the vehicle chassis, away from any
potential fuel vapour, and the other to a suitable earthing point.
Remove all combustible materials from the work area.
Use only containers rated for the fuel being drained. Ensure that the container mouth is as narrow
as possible while still allowing insertion of the drain hose.
HSE guidance recommends use of metal containers with secure caps for holding drained fuel.
Mark fuel containers with hazard labels to show their contents.
Keep any fuel containers in a well ventilated, lockable store, preferably outside the working area.
Soak up any spill immediately using absorbent granules or similar material.
Keep children and unauthorised persons away from the working area, especially when the drainer is
in operation. Keep the work area childproof by using padlocks and master switches.
Maintain the drainer in top condition. Keep it clean for best and safest performance.
Follow the same precautions when transferring fuel from the drainer back into the vehicle or into any
other container.
DO NOT use this drainer for anything other than its intended purpose. The drainer is only to be used
for pumping fuel from diesel or petrol vehicles.
DO NOT work on a fuel tank or remove a sender unit before draining the fuel.
DO NOT use an open flame or smoke anywhere near the drainer or around stored fuel.
DO NOT drain fuel into open-topped containers such as buckets and watering cans.
DO NOT drain fuel into dedicated workshop oil drain equipment.
DO NOT drain fuel into plastic containers except for quantities less than 10 litres.
DO NOT allow work which can produce a source of ignition, such as welding, electrical or other hot
work, to be carried out while draining petrol.
DO NOT drain fuel over, or close to, a pit or drain because of the risk of flammable vapour accumulation.
DO NOT use any electrical equipment on or near the vehicle while fuel draining is in
progress. This includes the use of inspection lights, cordless/mobile phones or pagers.
DO NOT store drained or contaminated fuel in the workplace unless it is to be returned to the vehicle immediately.
DO NOT add drained fuel to the waste oil tank.
DO NOT wear clothing on which petrol has been spilt - stop work and change into uncontaminated clothing before continuing to work.
DO NOT use the drainer if the pump is damaged in any way.
DO NOT stand on the drainer platform.
DO NOT leave pump running unattended. Turn it OFF and do not leave area until it has come to a complete stop.
DO NOT use whilst under the influence of drugs, alcohol or other intoxicating medication, or if you are fatigued.
DO NOT use the drainer for a job it was not designed to do.
Users/Businesses should perform their own hazard risk assessment based on their
specific environment and following the guidelines laid out above.
InSTRUCTIOnS FOR:
AIR OPERATED FUEL DRAINER
MODEL n
Original Language Version
TP200.V3
:
o
TP200.V3
Issue: 1 - 09/06/11

Advertisement

loading

Summary of Contents for Sealey TP200.V3

  • Page 1 AIR OPERATED FUEL DRAINER TP200.V3 MODEL n Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS, WARNINGS AND CAUTIONS.
  • Page 2 4.2. IMPORTANT. The TP200.V3 is fitted with an overflow hose system to prevent spillage in situations where the fuel tank capacity is greater than the capacity of the unit. Before drainage takes place the overflow hose must be placed into the neck of the vehicle’s fuel tank and the overflow valve (fig.2) must be opened by turning it to the vertical position.
  • Page 3 Unless the fuel is to be returned to the vehicle immediately, it should be stored in a designated lockable, well-ventilated area, preferably outside the workshop. 4.11. Any contaminated fuel or petrol/diesel mixtures should be consigned to waste, giving a clear description of the nature of the material. Original Language Version TP200.V3 Issue: 1 - 09/06/11...
  • Page 4 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...

This manual is also suitable for:

Tp200 v3