11.03
27204
PROFIsafe: Double assignment MD %1[%2] - MD %3[%4]
Parameter
%1 = MD name 1
%2 = MD field index for MD name 1
%3 = MD name 2
%4 = MD field index for MD name 2
Explanation
A double assignment has illegally been parameterized in the specified machine
data:
A_INSE parameterized on the DMP as well as PROFIsafe modules. MDs
involved:
- MD $MN_SAFE_IN_HW_ASSIGN
- MD $MN_PROFISAFE_IN_ASSIGN
$A_INSE parameterized on several PROFIsafe modules. MD involved:
- MD $MN_PROFISAFE_IN_ASSIGN
Response
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy
Correct the MD.
Program continuation
Power-down the control and power-up again.
27205
PROFIsafe: Number of signals in MD %1[%2] – MD %3[%4]
Parameter
%1 = MD name 1
%2 = MD field index to the MD name 1
%3 = MD name 2
%4 = MD field index to the MD name 2
Explanation
The parameterized number of signals used must be the same in both machine
data.
Response
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy
Correct the MD.
Program continuation
Power-down the control and power-up again.
27206
PROFIsafe: MD %1[%2] max. bit index %3 exceeded
Parameter
%1 MD name
%2 MD field index to the MD name
%3 max. bit index
Explanation
Data parameterized in the specified machine data lie outside the useful (net) F
data area of the F module.
Response
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy
Correct the MD.
Program continuation
Power-down the control and power-up again.
© Siemens AG 2003 All Rights Reserved