Sorter; Adjust - Canon imageRUNNER ADVANCE C5500 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

SORTER

ADJUST

SORTER > ADJUST
PNCH-Y
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Related Service Mode
Amount of Change per
Unit
STP-F1
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Amount of Change per
Unit
STP-R1
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Amount of Change per
Unit
Adj punch hole horz rgst pstn: Fin-H1/Y1
To adjust the punch hole in horizontal registration direction.
As the value is incremented by 1, the punch hole moves by 0.1 mm.
+: Toward rear
-: Toward front
When the punch hole is misaligned in the horizontal registration direction
Enter the setting value, and then press OK key.
When the setting of "PUN-Y-SW" is 0, the adjustable range is from -3 to 15.
-25 to 25
mm
SORTER> OPTION> PUN-Y-SW
0.1
Front 1-staple position: Fin-Y1
To adjust the front 1-staple position.
As the value is changed by 1, the staple position moves by 0.1 mm.
+: Toward rear
-: Toward front
When replacing the Finiser Controller PCB/clearing the RAM data of the Finiser
Controller PCB, enter the value of service label.
When the staple position in front/rear direction is displaced in the front 1-stapling mode
When replacing the Finiser Controller PCB/clearing the RAM data of the Finiser Controller PCB.
Enter the setting value, and then press OK key.
After the setting value is changed, write the changed value in the service label.
-30 to 30
mm
0.1
Rear 1-staple position: Fin-Y1
To adjust the rear 1-staple position.
As the value is changed by 1, the staple position moves by 0.1 mm.
+: Toward rear
-: Toward front
When replacing the Finiser Controller PCB/clearing the RAM data of the Finiser
Controller PCB, enter the value of service label.
When the staple position in front/rear direction is displaced in the rear 1-stapling mode
When replacing the Finiser Controller PCB/clearing the RAM data of the Finiser Controller PCB.
Enter the setting value, and then press OK key.
After the setting value is changed, write the changed value in the service label.
-30 to 30
mm
0.1
1075