Change The Feature Pack; Complete Host Protocol Conversion; Complete Nvme Over Infiniband, Nvme Over Roce Conversion, Or Nvme Over Fc - Fujitsu ETERNUS AB Series Hardware Maintenance Manual

Hide thumbs Also See for ETERNUS AB Series:
Table of Contents

Advertisement

What to do next
Go to

Change the feature pack

Change the feature pack
You change the feature pack to convert the host protocol of the host ports, the IB HIC ports, or both types of
ports.
Procedure
1. From SANtricity System Manager, select Settings > System.
2. Under Add-ons, select Change Feature Pack.
3. Click Browse, and then select the feature pack you want to apply.
4. Type CHANGE in the field.
5. Click Change.
The feature pack migration begins. Both controllers automatically reboot twice to allow the new feature
pack to take effect. The storage array returns to a responsive state after the reboot is complete.
6. Confirm the host ports have the protocol you expect.
a) From SANtricity System Manager, select Hardware.
b) Click Show back of shelf.
c) Select the graphic for either Controller A or Controller B.
d) Select View settings from the context menu.
e) Select the Host Interfaces tab.
f) Click Show more settings.
What to do next
Go to
Complete host protocol

Complete host protocol conversion

After converting the protocol of the host ports, you need to perform additional steps before you can use the
new protocol.

Complete NVMe over InfiniBand, NVMe over RoCE conversion, or NVMe over FC

After you apply the feature pack key to convert the protocol used by your NVMe over InfiniBand, or NVMe over
RocE, you need to configure the host to use the appropriate protocol.
Procedure
Configure the host to use the NVMe protocol.
For step-by-step instructions on how to configure the host to use NVMe, see the
conversion.
 | Host port protocol conversion |
Linux express
configuration.