Symbols; Sizing; Derating - ABB ACS800 Series Hardware Manual

Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

ACS800-U1 size
Three-phase supply voltage 525 V, 575 V, 600 V
-0011-7
14
-0016-7
19
-0020-7
28
-0025-7
38
-0030-7
44
-0040-7
54
-0050-7
68
-0060-7
84
-0070-7
104
-0100-7
124
-0120-7
172
-0145-7
190
-0175-7
245
-0205-7
245
Overload may be limited to 5% at high speeds (> 90% speed) by the internal power limit of the drive.
1)
The limitation also depends on motor characteristics and network voltage.
2)
Overload may be limited to 40% at high speeds (> 90% speed) by the internal power limit of the
drive. The limitation also depends on motor characteristics and network voltage.
3)
Special 4-pole high-efficiency NEMA motor
Higher rating is available with special 4-pole high-efficiency NEMA motor
4)
Type not available any more.
5)

Symbols

Nominal ratings
I
maximum output current. Available for 10 s at start, otherwise as long as allowed by drive
max
temperature.
Normal use (10% overload capability)
I
continuous rms current. 10% overload is typically allowed for one minute every 5 minutes.
2N
P
typical motor power. The power ratings apply to most 4-pole NEMA rated motors (230 V,
N
460 V or 575 V).
Heavy-duty use (50% overload capability)
I
continuous rms current. 50% overload is typically allowed for one minute every 5 minutes.
2hd
P
typical motor power. The power ratings apply to most 4-pole NEMA rated motors (230 V,
hd
460 V or 575 V).
Note 1: The ratings apply at an ambient temperature of 40 °C (104 °F). In lower temperatures the
ratings are higher (except I

Sizing

See page 107.

Derating

See page 108.
I
Normal use
max
I
P
2N
N
A
A
hp
11.5
10
15
10
20
15/20
4)
23
20
30
25/30
4)
34
30
46
40
52
50
73
60
86
75
108
100
125
125
155
150
192
200
).
max
Heavy-duty use
Frame
size
I
P
2hd
hd
A
hp
8.5
7.5
R4
11
10
R4
15
15
R4
2)
20
20
2)
R4
25
25
2)
R4
30
30
2)
R4
40
40
2)
R5
42
40
R5
54
50
R6
62
60
R6
86
75
R6
99
100
R6
131
125
R6
147
150
R6
119
Air flow
Heat
dissipation
3
ft
/min
BTU/Hr
61
1050
61
1200
61
1550
61
1850
61
2100
61
2400
147
2900
147
3450
238
4200
238
5650
238
6700
238
9100
238
11850
238
14300
00096931
Technical data

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-01 seriesAcs800-u1 seriesAcs800-01-0001-2Acs800-01-0002-2Acs800-01-0003-2Acs800-01-0004-2 ... Show all

Table of Contents