Rotating the connector for 1FK7xxx-2, 1FK7xxx-3, 1FK7xxx-4

Power connectors and signal connectors can be rotated to a limited extent. A suitable socket
connector can be used to rotate the angle plug. Make sure that the socket connector is
completely secure to avoid damaging the pin contacts. For encoders with integrated Sensor
Modules (DQI) the cable outlet towards the top is fixed and cannot be changed.
NOTICE
Rotating the connectors
 It is not permissible that the specified rotation range is exceeded.
 In order to guarantee the degree of protection, max. 10 revolutions are permissible.
 Connectors should be rotated using the matching mating connector located on the
Ability to rotate the power connector for motors with DRIVE-CLiQ interface without Sensor Modules
1FK7□□□-□□□□□-□X□□; X = B, C, Q, R
Table 6- 4
Rotation range of the power connector
Motor
Angle α
1FK703
122°
1FK704
1FK706
135°
1FK708
1FK710
1FK708
195°
1FK710
Synchronous Motors 1FK7
Operating Instructions, 03/2011, 610.40700.40c
connector thread. Only rotate Sensor Modules by hand. The use of pipe wrenches,
hammers, or similar is not permitted.
Angle β
Connector size
208°
195°
140°
Drawing
1
1
1.5
Connecting