INSTMLIHG ~BIHETS OVER YOUR COOKTOP
I:-n%o II
~
lmi"towall(2.54cm)
We recommend at least 6 (15.24
cm) for best venting performance.
Avoidplacing cabinets above the cooktop unit,
if possible, in order to reduce the hazards caused
by reaching overheated surface units.
Make sure the wall coverings around the
cooktop can withstand heat generated by the
cooktop
UP
to 200°F
If cabinets are placed above the cooktop, allow
a minimum clearance of 3V between the cooking
surface and the bottom of unprotected cabinets
unless the underside of the cabinets above the
cooktop is protected with not less than 1/4'
insulating flame-retirdant millboard covered
with sheet metal not less than 0.012Y
( 0.031cm) thick.
Clearance between the cooking surface and
protected cabinets MU= NE~R BE LESS
H
24 INCHES.me vertical distance from
the plane of the cooking surface to the bottom of
adjacent overhead cabinets extending closer
than 1"to the plane of the cooktop sides must
not be less than lV.
~CE~ON:
Instillation of a fisted microwave
oven or cooking appfianceover the cooktop shall
conform to the installationinstructions packed
with that appfiance.
Working areas adjacent to the cooktop should
have an lV (45.7cm) minimum clearance
between the countertop and the bottom of the
cabinet. E the clearance is less than lW
(45.7cm), the adjacent cabinets should beat
least V (5.08cm) from the side of the cooktop.
ProperElectrical Supply
Youmust provide an adequate electrical supply
system as required for your cooktop.N1 wire
connections must be in accordance with local
codes and properly insulated. Check with local
utitityfor governing electrical codes and
ordinances. In the absence of local electrical
codes, the national Electrical Code, NFPA No.
70, must be followed.A copy of the National
Electrical Code, NFPA No. 70, can be obtained
by writing to:
National Fire Protection Assoc.
Batterymarch Park
Quincy,Massachusetts 02269
A threewire, single phase, A.C. 120/240volt or
120/208volt, 60 cycle electrical system @roperly
circuit protected to meet bcal Codes or NFPA
No. 70) must be provided. Unit must be properly
grounded in accordance with localwiring code.
me followingchart recommends the minimum
circuit protection and wire size if the appfianceis
the only unit on the circuit. If smaller sizes of
wire are used, the unit efficiencywillbe reduced
and afire hmard maybe created. It is advisable
that the electrical wiring and hookup be
accomplished by a competent electrician.
(continued next page)