Bosch Access Easy Controller Hardware Manual page 40

Hide thumbs Also See for Access Easy Controller:
Table of Contents

Advertisement

40
en | How to Install Reader and Field Devices
HI D Reader
Jumpers and Switch Setti n g
P1
P2
No Connect i on
for Keypad onl y
P3
P3
1
8
If you need to turn the beeper OFF,
move SW1-2 to OFF posit i on
Ver 2.0.0 | 2006.07
T7
T8
RED
BLACK
GREEN
WHITE
ORANGE
T9
T10
CN1
T11
CN2
BELDEN 9944
HID PROXPRO with KeyPad Connector
RED
1
+12 VDC
BLACK
2
Ground
GREEN
3
Data 0
WHITE
4
Data 1
ORANGE
5
Green LED
6
Red LED
7
Beeper
Indicates swi t ch posit i on
8
Hold
9
Tamper Common
10
Tamper Select
Hardware Manual
T6
T2
1
1
J1
T3
T4
JP1
J2
JP2
JP3
T5
1
T1
DOOR CONTACT
6. 8 K Ohm
-
+
DOOR
STRI K E
Access Easy Controller
-
+
What i s bei n g set u p
HI D Pr o xPro wi t h KeyPad Reader
Nor m al l y Open Exi t Devi c e
Nor m al l y Cl o se Door Contact
Fai l - Saf e r DC Door Str i k e
6. 8 K Ohm
EXI T DEVI C E
Bosch Security Systems