5

Cables

1070 080 086-101 (01.01) GB
PSI 6XXX.190 W1
Cables and cable lengths.
Interface
X1, programming terminal
(V 24)
X2, pressure
analog pressure output
Pressure input
Transformer temperature
X4, power supply
X5, external device
X10, power supply
X11, parallel outputs
A0
A1 to A12
(+24 V/0.1 A)
X12, X13,
parallel inputs
E0 to E20
Cable
shielded cable
shielded cable
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
unshielded cable,
VDE 0281, 0812
e.g. Ölflex
Cables
Cross section/max. length
2
min. 0.2 mm
up to 20 m
2
e.g. 3 x 2 x 0.2 mm
LifYCY (Metrofunk)
capacitance max. 2.5 nF
2
0.5 mm
up to 50 m
2
0.75 mm
up to 100 m
e.g. NFL 13 (Metrofunk) or
LiYCY
2
0.5 mm
2
0.5 mm
2
0.75 mm
up to 10 m
2
1.5 mm
up to 75 m
2
0.75 mm
up to 10 m
2
1.5 mm
up to 75 m
2
0.75 mm
up to 10 m
2
1.5 mm
up to 75 m
2
0.5 mm
up to 30 m
2
1.0 mm
up to 50 m
2
1.5 mm
up to 100 m
2
0.5 mm
up to 100 m
2
0.5 mm
up to 100 m
5-1