9.2

Programming the Welding Parameters

Schedule (Sequence)
Current Monitoring
1070 080 086-101 (01.01) GB
PSI 6XXX.190 W1
Dividing the Welding Parameters of a seam program between the basic program and the
block programs:
x: the Welding Parameters are programmed in a basic or block program designated
with an x
-: the Welding Parameters in the basic or block program are not used.
Welding Parameters
Slope on / off
Pre-Squeeze Time [1.SQZ]
Squeeze Time [SQZ]
Block delay time [BDT]
as Pre-Squeeze Time [1. SQZ]
1st Weld Time [1. WLD] with %I and Regulation Mode
1st Cool Time [1. CT]
Up Slope Time [UST]
2nd Weld Time [2. WLD] with %I and Regulation Mode
Down Slope Time [DST] with %I
2nd Cool Time [2. CT]
3rd Cool Time [3. CT]
3rd Weld Time [3. WLD] with %I and Regulation Mode
Hold Time [HLD]
OFF Time [OFF]
Impulse
Parameters
Standard Monitoring mode
Monitoring Parameters Mixed 1st Weld time [1. WLD]
Monitoring Parameters Mixed 2nd Weld time [2. WLD]
Monitoring Parameters Mixed 3rd Weld time [3. WLD]
BOS-5000
Basic
Block
program
program
x
x
x
-
x
-
-
x
-
-
-
-
-
x
-
x
-
-
-
x
-
-
-
-
x
-
-
-
-
-
Basic
Block
program
program
-
-
-
-
-
x
-
-
9-3