9.3

Input ranges of the Welding Parameters

1070 080 086-101 (01.01) GB
PSI 6XXX.190 W1
-
Pre-Squeeze Time
-
Squeeze Time
-
1st to 7th Block delay time
(as Pre-Squeeze Time [1. SQZ] in the block programs)
-
1st to 7th Current slope time
-
1st to 7th Weld time
-
1st to 7th Cool Time
-
1st to 7th Regulation mode
-
1st to 7th %I KSR
-
1st to 7th %I PHA
-
Hold Time
:
0 to 2000 ms
:
16 to 2000 ms
:
0
to 2000 ms
:
0
to 2000 ms
:
1
to 2000 ms
:
0
to 2000 ms
:
PHA or KSR
:
depends on the welding transformer used
:
0
to 100 SKT
:
1
to 2000 ms
BOS-5000
9-5