Fujitsu BS2000 SE Series Manual page 21

Hide thumbs Also See for BS2000 SE Series:
Table of Contents

Advertisement

Powering on, starting up BS2000, powering off
Open the KVP menu with the function key [F2] (on the keyboard or on a virtual keyboard
Ê
on the console window):
Main KVP Function Menu
==========================================================================
0 - Exit
4 - View last messages
5 - Show logging files
6 - SVP commands
7 - Programmable function keys
8 - Help
==========================================================================
Please enter value:
Click behind Please enter value: and enter the value 6 to display the menu with the SVP
Ê
commands:
SVP commands
==========================================================================
0 - Back to main menu
1 - Start BS2000
2 - Start BS2000 dump IPL
3 - Dump IOH memory
4 - Report actual default parameters for IPL
==========================================================================
Please enter value:
Enter the value 1 to display the menu containing the IPL functions for starting BS2000:
Ê
Start BS2000
==========================================================================
0 - Back to main menu
1 - Execute with current parameters
2 - Execute with preset parameters
3 - Execute with current parameters and save into preset parameters
Change params:
a - IPL load device:
b - Consol device:
c - Startup mode [a|d|f]:
d - BS2000 systemname:
e - Clear BS2000 memory [y|n]:
==========================================================================
Please enter value:
The menu shows, among other things, the (current and preset) load device (also called
IPL or boot load device) of BS2000. As the Server Unit was rebooted, the IPL load
device from the auto IPL configuration is set. This can differ from the IPL load device of
the last IPL. If necessary, use menu item a to select a different IPL load device.
I
Enter the value 1 to save the settings and start the IPL. This action closes the KVP and
Ê
the current console messages are displayed.
U41857-J-Z125-2-76
Initial startup from the IPL load device requires a DIALOG startup. For this
purpose the value d must be set for the IPL parameter Startup mode. If
necessary, select this value using menu item c.
Booting the BS2000 on an SU x86
current
9908
Z0
a
ABGAFR01
n
preset parameters
9908
Z0
f
ABGAFR01
n
21