Release 7.0.0 3DB 19286 ACAA Issue 01
WebEML User Manual
3. Install optical Ethernet fiber from MSS-4/8 shelf to MPT ODU as required per
4. Verify that the MPT ODU radio interface is not associated with the following:
5. Perform a database backup. See
6. If MPT ODU radio interface is configured for 1+1 HSB/FD/SD, downgrade radio
7. Disable MPT ODU radio port from MPTACC card. See
8. If MPTACC PFoE is the power source for the MPT ODU, verify the power source
9. If MPTACC card is to be replaced with P8ETH card to support L1 LAG port.
10. Verify/enable P8ETH card to support L1 LAG port.
Note: Electrical SFPs are not supported for interconnection between P8ETH SFP port and
MPT ODU.
11. Install SFP into the P8ETH radio port and connect fiber cable to SFP. L1 LAG
12. Install SFP into the MPT ODU data port and connect the fiber cable to the SFP
13. Provision MPT ODU radio interface.
site documentation.
a. Cross-Connection
b. VLAN
c. Port Segregation
d. PPP RF enabled
e. Synchronization reference
f. SSM
restore)
for a detailed procedure to perform a database backup.
protection to 1+0. See
Upgrade and downgrade protection
procedure.
detailed procedure.
is still configured for PFoE.
Perform the following actions:
a. Verify no radio interfaces are supported on the remaining MPTACC radio
interface. If there is a radio interface connected to the remaining MPTACC
radio port, STOP this procedure immediately and contact the next level of
support!
b. Disable MPTACC card. See
c. Remove the MPTACC card from the MSS-4/8 shelf.
d. Install the P8ETH card into the MSS-4/8 shelf.
Master port must reside in P8ETH Ethernet port 5 or 7.
per site documentation.
Upgrade MPT ODU to MPT ODU L1 LAG port
MIB database management (backup and
Disable equipment
Disable equipment
for a detailed procedure.
for a detailed
for a