Table 3-19
Emergency stop override X21
Connector designation: X21
Connector type:
Cable length (max.):
Table 3-20
Note
Emergency stop X21: Operating voltage: 24 V DC; switched current: max. 500 mA.
Machine Pushbutton Panel: MPP 464 IE H
Equipment Manual, 03/2021, A5E50810237B AA
Enabling X20
Pin
Signal name
1
ZUST1P
2
ZUST1M
3
ZUST2P
4
ZUST2M
5
N.C.
6
N.C.
7
N.C.
8
N.C.
MCV 1.5/10-G3.81
30 m
Emergency stop override X21
Pin
Signal name
1
STOP23
2
STOP24
3
STOP13
4
STOP14
5
M
6
N.C.
7
IN_E9
8
P24_FILT
9
IN_E9_EXT
10
IN_E12_EXT
Type
Meaning
I
Electronic acknowledgement button 1P
O
Electronic acknowledgement button 1M
I
Electronic acknowledgement button 2P
O
Electronic acknowledgement button 2M
Not assigned
Not assigned
Not assigned
Not assigned
Type
Meaning
Emergency stop NC contact 1.1
I/O
Emergency stop NC contact 1.1
Emergency stop NC contact 2.1
Emergency stop NC contact 2.2
V
-
Not assigned
I
Emergency stop override negated
V
24 V
Keyswitch actuated
O
Terminating connector plugged in
Description
3.4 Interfaces
31