Set-Ant" Acknowledgement; Set-Rs232" Command - Siemens SIMATIC Ident RF200 Operating Manual

Ascii protocol
Hide thumbs Also See for SIMATIC Ident RF200:
Table of Contents

Advertisement

2.7

"SET-ANT" acknowledgement

Table 2- 12
"SET-ANT" acknowledgement
Address
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Table 2- 13
"SET-ANT" acknowledgement
Address
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
2.8

"SET-RS232" command

Table 2- 14
"SET-RS232" command
Address
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
Designation
Frame length
Command
Status
Mode
Designation
Frame length
Command
Status
Designation
Frame length
Command
Status
Baud rate
Value
0x30
0x33
0x30
0x30
0x30
0x41
0x30
0x31 / 0x32
Value
0x30
0x32
0x30
0x41
high nibble
low nibble
Value
0x30
0x35
0x42
0x42
0x30
0x30
0x30
0x31 / 0x33 / 0x35
Command and message frames
2.7 "SET-ANT" acknowledgement
Description
Net data length of the frame - 1
byte
--
--
0x31 ≙ antenna on
0x31 ≙ antenna off
Description
Net data length of the frame - 1
byte
--
Error code "error_Moby"
Description
Net data length of the frame - 1
byte
New command
--
0x31 ≙ 19.2 kBd
0x33 ≙ 57.6 kBd
0x35 ≙ 115.2 kBd