Siemens SIMATIC Ident RF200 Operating Manual page 27

Ascii protocol
Hide thumbs Also See for SIMATIC Ident RF200:
Table of Contents

Advertisement

The "Transmission in ASCII format" setting means that the four higher-order bits are
converted and transmitted first followed by the four least significant bits, irrespective of the
"ByteOrder" parameter.
Data description
The following table lists all parameters available in the reader. The byte indication refers to
the entry in the "Change parameter" frame to the reader.
If a parameter value consists of two bytes, the MSB is always transferred first. The bolded
value in a cell in the "Value" column is the preset default value.
Table 3- 5
Description of the parameters
Byte
Value
Meaning
0
21
21
1
0
reserved
1
ISO general
255
ISO user-
defined
2
30
30 %
0-100
0-100 %
3
0
single
1
double
4
0
high
1
low
5
0
Single tag
1
reserved
6
0
Continuous
Read
1
Single Read
2
Scanmode Off
3
Single Read
repeated
7 + 8
10
10 * 100 ms
1...6553
(1...65535) *
5
100 ms
9
re-
--
served
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
Description
Current length of the parameters in the frame (in bytes). This value is always 21.
Tag type
Setting of the air interface/transponder used
Modulation
Air interface optimization: setting is only possible by selecting "ISO user-defined"
Subcarrier
Air interface optimization: setting is only possible by selecting "ISO user-defined"
Data rate
Air interface optimization: setting is only possible by selecting "ISO user-defined"
Operating mode
Only single tag setting is possible. If there are multiple transponders in the antenna
field, these are not identified and cannot be processed.
Scan mode
Selection of scan mode sequence
Continuous read: Read operations are executed continuously. The "Locktime"
parameter defines the distance between read operations. All UIDs of identified
transponders are reported. The UID of a single transponder can be reported mul-
tiple times.
Single read: Read operations are executed continuously. All UIDs of identified
transponders are reported one time. A single UID cannot be reported multiple
times in succession, even if the transponder is in the antenna field for an extend-
ed period. The UID must first change.
Single read repeated: Read operations are executed continuously. All UIDs of
identified transponders are reported. The UID of a single transponder can be re-
ported multiple times.
Lock time
Setting for lock time duration for continuous read mode
Transmit power
Transmit power setting to optimize communication with the transponder. Only possi-
ble with RF38xR.
Scan mode function extension for ASCII readers
3.3 Communication in scan mode
27

Hide quick links: