Scan mode function extension for ASCII readers

3.4 Error messages

3.4
Error messages
Error messages
The error code is always stored in byte 2 of the acknowledgment. Error Code "00" is always
output when a frame is processed without errors. Error code ≠ 00 means that the parameters
have not been accepted. The following table lists all possible error codes.
Table 3- 19
Error code
0x01
0x02
0x03
0x04
0x05
0x06
0x07
32
Error messages
Description
Command is unknown (in first byte of frame).
Status is unknown (in second byte of frame).
A parameter setting is faulty.
BCC is faulty (in last byte of frame).
Data could not be stored retentively
(FEPROM are not identified).
Data could not be stored retentively
(FEPROM sector cannot be deleted).
Data could not be stored retentively
(FEPROM sector cannot be programmed).
ASCII protocol for RF200