Level Calibration Check (X-axis)
Position a tripod securely on the floor between two walls that are
1.
at least 15m apart. The exact location of the tripod is not critical.
Make sure that the top of the tripod is roughly level.
2.
• The laser will self-level only if the top of the tripod is within ±
5˚ of level.
• If the laser is set up too far out of level, it will beep when it
reaches the limit of its leveling range. No damage will be done
to the laser, but it will not operate in an "out of level" condition.
Attach a tripod adapter (Figure
3.
adapter may be assembled to the bottom for level mode or to
the side for plumb mode.
Place the laser with the attached adapter on the tripod and
4.
screw the threaded knob on the tripod into the female thread on
the tripod adapter.
Position the laser unit with the tripod so that the laser's X-axis
5.
points directly toward one of the walls (Figure
Turn the laser unit on and allow it to self-level.
6.
Where the beam appears on the left wall, mark point A, and
7.
where the beam appears on the right wall mark point B.
Turn the laser unit 180º so that the X-axis points directly toward
8.
the opposite wall (Figure
Allow the laser unit to self-level.
9.
Where the beam appears on the left wall, mark point AA, and
10.
where the beam appears on the right wall mark point BB.
Calculate the Total Error using the following equation:
11.
Total Error = (AA-A) - (BB-B)
) to the laser unit. The
G
1
).
L
1
).
L
2
If your Total Error measurement is greater than the Allowable
12.
Error for the corresponding Distance Between Walls in the
following table, the laser must be serviced at an authorized
service center.
L (Distance Between
Walls)
15m (40')
20m (50')
25m (70')
30m (100')
Level Calibration Check (Y-axis)
Set up a tripod between two walls that are at least 15m apart.
1.
The exact location of the tripod is not critical.
Make sure that the top of the tripod is roughly level.
2.
• The laser will self-level only if the top of the tripod is within ±
5˚ of level.
• If the laser is set up too far out of level, it will beep when it
reaches the limit of its leveling range. No damage will be done
to the laser, but it will not operate in an "out of level" condition.
Attach a tripod adapter (Figure
3.
adapter may be assembled to the bottom for level mode or to
the side for plumb mode.
Place the laser with the attached adapter on the tripod and
4.
screw the threaded knob on the tripod into the female thread on
the tripod adapter.
Position the laser unit with the tripod so that the laser's Y-axis
5.
points directly toward one of the walls (Figure
Turn the laser unit on and allow it to self-level.
6.
Where the beam appears on the left wall, mark point A, and
7.
where the beam appears on the right wall mark point B.
Turn the laser unit 180º so that the Y-axis points directly toward
8.
the opposite wall (Figure
Allow the laser unit to self-level.
9.
Where the beam appears on the left wall, mark point AA, and
10.
where the beam appears on the right wall mark point BB.
Allowable Error
1.5mm (3/64")
2mm (1/16")
2.5mm (3/32")
3mm (1/8")
) to the laser unit. The
G
1
).
M 1
).
M 2
GB
17

Advertisement

loading

This manual is also suitable for:

Dce080gs