About this product | Automax 100 | Extension module TS-AC E2-M3-1X
Port for current measurement
Schematic diagram of analog inputs
The technical data of analog inputs is described in the following table. These must always
be observed for selection of sensors to be connected.

Technical data of analog inputs

Technical data of analog inputs
Analog inputs
Number of inputs
Connection type
Current input signal
Resolution A/D
A/D conversion time
Limit frequency (3 dB)
Measuring value illustration
Transient protection of inputs
Overload protection

Local diagnostics and status indicators

Local diagnostics and status indicators
Connection of pressure sensor,
internal voltage supply
4
2, 3, 4-wire (shielded)
0 mA ... 20 mA , 4 mA ... 20 mA , -20 mA ... 20 mA
16 bit
31.25 μs
30 Hz , 12 kHz
16 bit (15 bit + sign)
Suppressor diode
no; max. DC ±5,2 V, Imax = 50 mA
Bosch Rexroth AG | 05.2021 | DOK-SUPPL*-TS-AC E2-M3-ITRS-EN-P