Download Print this page

Huawei OptiX RTN 320 Quick Installation Manual page 10

Advertisement

Installing the OAU 2A
2
Installation at a 2+0 or 1+1 Site
Installation procedure
1
Install an OAU 2A on a wall or pole.
• Determine whether to install an OAU 2A on a wall or pole based on
actual conditions.
• If an OAU 2A needs to be installed on a tower, it is recommended that
you install it at the foot of the tower to facilitate maintenance.
2
Install a ground cable.
Install the device-side ground cable before you climb up the tower.
Install IF cables.
3
Connect the IF ports of the OAU 2A and each XMC ODU using an IF
cable.
For the method of making and laying out an IF cable, see the RTN XMC
ODU Quick Installation Guide.
Do not remove or insert an IF cable connector from or to the OAU 2A with
power on. Otherwise, human injuries may be caused.
Install an outdoor fiber or network cable.
4
• Connect an outdoor fiber or network cable to a port in the
maintenance compartment.
• Lay out the outdoor fiber or network cable.
• Attach a yellow label to the fiber or network cable, and write a
number on the label according to the plan.
Install a DC power cable.
5
• Connect a DC power cable to the DC power port in the maintenance
compartment.
• Lay out the DC power cable.
• Select ground points for the DC power cable, and install ground clips.
• Attach a matte white label to the DC power cable.
Before installing a cable, bind the cable section that links the cable connector
to the pole. This will protect the cable connector from damage. Ensure that
the length of cable running from the binding point to the OAU 2A is sufficient
to attach the cable connector to a service port on the OAU 2A.
6
Waterproof ground clips and IF cable connectors.
For the method of installing an antenna,
follow the antenna installation guide
delivered with the antenna.
6
3
1
GE3(o)
PWR
IF2
IF1
2
6
6
Connected to a
power supply
device
5
4
To a NodeB
DC
power
cable
Grounded using
DC
a ground clip
power
cable
6
9
For the methods of installing an
XMC ODU and a hybrid coupler,
see the RTN XMC ODU Quick
6
Installation Guide.
3
The GE1(e) or GE2(e) port can be used
to transmit/receive electrical services,
and the GE3(o) or COMBO port can be
used to transmit/receive optical services.
In this example, the GE3(o) port is used.
Commissioning procedure
Power on the OAU 2A.
1
Use the Web LCT to configure NE data.
2
3
Align antennas.
You can use an alignment scope to
align antennas. For details about how
to install an alignment scope, see the
appendix.
Check the installation.
4