Configuration And Settings; Configuring Logo! Cmr For Sending/Receiving Sms Messages - Siemens LOGO! 8 Manual

Street light control
Hide thumbs Also See for LOGO! 8:
Table of Contents

Advertisement

4 Configuration and Settings

4.1 Configuring LOGO! CMR for sending/receiving SMS messages

To enable writing a new value to analog network input NAI2, it must first be reset.
Analog network input NAI2 is reset by analog MUX (function block B015) via output
AQ, to which the same address VW8 has been assigned by address network input
NAI2 via the parameter VM mapping table.
As soon as a new value is written to analog network input NAI2, output AQ is set to
"0" after 2 seconds by the analog MUX (function B015). This resets the analog
network input NAI2 automatically back to "0".
4
Configuration and Settings
Note
In this application example, a completed configuration file for LOGO! CMR is
offered for download. In the configuration file, the following settings have
already been made:
Please ensure that when loading the configuration for the LOGO! CMR, the
password of the configuration file is also adopted.
In this application, password "LOGO8cmr." was assigned in the configuration
for the user "Staff" as well as for the user "admin". In addition, password
"SMSwrite" was specified in the configuration as password for write
commands via SMS. In the web interface (WBM) of LOGO! CMR you can
change the password for the user and the password for write commands via
SMS at any time.
Further information, on how to load the completed configuration file into LOGO!
CMR is available in Chapters 5.3.2.
4.1
Configuring LOGO! CMR for sending/receiving SMS
messages
The tables below contain descriptions on the settings necessary in the web
interface (WBM) of LOGO! CMR to enable sending or receiving an SMS with
LOGO! CMR.
Note
It is assumed that LOGO! CMR has been connected to a power supply,
connected to a PC network, and that a SIM card has been inserted.
Please ensure that the IP address of the network connection of your PC
(or USB Ethernet adapter) used for connecting to LOGO! 8 is located in the
same subnet as the LOGO! device and the LOGO! TDE. An instruction
on how to change the IP address of a network card is available, for example, on
the internet in the Microsoft Knowledge Base at
Table 4-1
No.
1.
Open your Web browser and enter the IP address of LOGO! CMR (factory setting: 192.168.0.3).
2.
The web interface (WBM) of LOGO! CMR automatically opens.
LOGO! Set 1
Entry ID: 109063024,
V1.0,
Settings for receiving and sending SMS messages
Settings for monitoring the signals from the LOGO! program
Settings for time-of-day synchronization via NTP server
07/2015
"Changing TCP/IP
Action
settings".