1. Insert the device with its mounting seal, clamping frame and all enclosed mounting clips
into the mounting cut-out from the front, as shown in the figure.
The tip of the setscrew must be inserted into the center hole as shown in the zoomed
section of the figure.
2. Turn the setscrew of each mounting clip until a slight clamping force is perceptible.
After a few rotations a slight resistance will become perceptible. When the increase in force
is perceptible, tighten the setscrew of the next mounting clip. Perform this step for all
setscrews.
3. Check that the mounting seal is properly seated.
– The edge of the mounting seal must be flush and evenly flush with the stainless steel
– The edge may protrude 0.1 to 0.5 mm.
4. Tighten the setscrew of the mounting clip until the fixed stop is reached and the torque
increases perceptibly. The tightening torque is then:
– With 7, 9, and 12" devices: approx. 1.0 Nm
– With 15" and 19" devices: approx. 0.5 Nm
5. Check that the stainless steel front is in contact with the mounting location on all sides and
that the mounting seal is pressed against the surrounding area.
6. Check that the fixed stop has been reached on all mounting clips and that the mounting
gasket is installed correctly. Correct the tightening torque, if necessary, so that the clamping
force is evenly distributed.
Removal
For removal, follow the steps for installation in reverse order. Dispose of the used mounting
gasket.
Comfort Panels INOX PCT
Compact Operating Instructions, 07/2021, A5E38804191-AE
Material thickness t at the
mounting cutout:
front on all sides.
Installing and connecting the device
With 7, 9, and 12" devices: 1.5 mm to 6 mm
With 15" and 19" devices: 1.5 mm to 5 mm
3.3 Mounting the device