Technical specifications
5.8 Technical specifications
Power supply
Comfort HMI devices
Rated voltage
Permitted voltage range
Rated current
Rated current, load-dependent
Inrush current I
t
2
Power consumption
1
Maximum permitted transient
Minimum time between two transients
Internal protection
The power loss generally corresponds to the specified value for power consumption.
1
See also
Notes on installation (Page 22)
48
TP700 Comfort
TP900 Comfort
INOX PCT
24 V DC
+19.2 V to +28.8 V
0.5 A
0.5 A to 0.85 A
0.75 A to 1.05 A
12 W
35 V (500 ms)
Compact Operating Instructions, 07/2021, A5E38804191-AE
TP1200 Comfort
INOX PCT
INOX PCT
0.75 A
0.85 A
0.85 A to 1.20 A
0.5 A
s
2
18 W
20 W
50 s
Yes