8.5.5 To remove the soft start unit and the
electronic filter (S 36)
WARNING: Use approved personal protection
when you remove the HEPA filter. Refer to
replace the HEPA filter on page 17 .
1. Remove the hoses from the HEPA filters.
2. Loosen the nuts and pull the HEPA filters up. Put the
HEPA filters in a sealed container.
3. Remove the motor tube gaskets.
24 - Repair instructions
4. Spray glass cleaning agent on the tubes to make it
easy to remove the top of the motor housing.
To
5. Remove the 3 screws and remove the top of the
motor housing.