Scheduled maintenance
Planned maintenance at specific time intervals, including the following checks and
actions:
… All points under frequent checks
… Check all pressure levels
… Check for stable temperature levels around the system
… Drain water and sludge from the tank at the drain tap
… Check the electric motor
… Check the function of monitoring equipment/switches, etc
… Cleaning.
High pressure washing
Damage on equipment
Never use a high pressure washing system to clean inside the drive unit
… Check the cables
… Check drain line flows and drain line oil condition
… Check the hoses, couplings and pump(s), with respect to cracks, leakages and
condition
… Check the shaft coupling through the inspection hole.
… Check the air filter in the control unit
Rotating parts!
Risk of injury.
Do not touch rotating parts.
… Check that the panels of the drive unit not are damaged
Table 11: Maintenace chart
Absolute max. intervals for major
inspection and replacement
After the first 100 working hours
After 3 months or 500 working hours
Once every 3 months
Once every 6 months
Once every 12 months
I = Inspection
R = Replacement
*If the contamination indicator is tripped out, the filter must be changed immediately and the oil
examined.
Hägglunds DOb, RE 15327-WA/05.2017, Installation and maintenance manual, Bosch Rexroth AB
Maintenance and repair
NOTice
CAUTIoN
Filter control
Oil filters
cabinet
-
R*
-
R*
I
-
-
-
-
R*
63/80
Air breather
Hydraulic
on tank
fluid
-
-
-
-
-
-
-
I
R
-