Electro-Magnetic Immunity
This EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
Immunity Test
Electrostatic discharge (ESD) IEC
± 8 kV contact
61000-4-2
± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air
Electrical fast transient/burst IEC
± 2 kV
61000-4-4
100 kHz repetition frequency
Surge Line-to-line IEC 61000-4-5
± 0,5 kV, ± 1 kV
Surge Line-to-ground IEC 61000-4-5
± 0,5 kV, ± 1 kV, ± 2 kV
Voltage dips IEC 61000-4-11
0 % U
; 0,5 cycle
T
At 0 °, 45 °, 90 °, 135 °, 180 °, 225 °, 270 ° and 315 °
0 % U
; 1 cycle
T
and
70 % U
; 25/30 cycles
T
Single phase: at 0 °
Voltage interruptions IEC 61000-4-11
0 % U
; 250/300 cycle
T
RATED power frequency magnetic fields
30 A/m
(50/60Hz) IEC 61000-4-8
NOTE
is the A.C mains voltage prior to application of the test level.
U
T
IEC 60601-1-2 Test Level
± 8 kV contact
± 15 kV air
± 2 kV
100 kHz repetition frequency
± 1 kV
± 2 kV
0 % U
; 0,5 cycle
T
At 0 °, 45 °, 90 °, 135 °, 180 °, 225 °, 270 ° and 315 °
0 % U
; 1 cycle
T
and
70 % U
; 25/30 cycles
T
Single phase: at 0 °
0 % U
; 250/300 cycle
T
30 A/m
Compliance Level
Electromagnetic Environment – Guidance
Floors should be wood, concrete or ceramic tile. If floors are
covered with synthetic material, the relative humidity should be
at least 30 %.
Mains power quality should be that of a typical commercial or
hospital environment.
Mains power quality should be that of a typical commercial or
hospital environment.
Mains power quality should be that of a typical commercial or
hospital environment. If the user of the EUT image intensifier
requires continued operation during power mains interruptions, it
is recommended that the EUT image intensifier be powered from
an uninterruptible power supply or a battery.
Power frequency magnetic fields should be at levels characteristic
of a typical location in a typical commercial or hospital
environment.