Connection To Metpoint ® Bdl Compact; Bidirectional Rs485 Bus System; Current Output 4 - Beko METPOINT FLM SF13 Installation And Operating Manual

Thermal flow meter
Table of Contents

Advertisement

Installation and operating manual
4.4. Connection to METPOINT

4.4.1. Bidirectional RS485 bus system

Connection by means of plug-type connector A.
Connection diagram for METPOINT
q
Pin assignment - sensor
PIN-1
+ U
V
PIN-3
- U
V
PIN-2
+ A
PIN-4
- B
PIN-5
4.4.2. Current output 4 ... 20 mA, 3-wire
Connection by means of plug-type connector A.
Connection diagram for METPOINT
Pin assignment - sensor
PIN-1
+ U
V
PIN-3
- U
V
PIN-5
+ I
OUT
PIN-2
PIN-4
22
BDL compact
®
SF13 and METPOINT
®
1
+ U
V
V
3
- U
V
2
+
A
-
4
RS485
B
Function
Plus (+) connection, power supply
Minus (-) connection, power supply
Non-inverted signal (+) from RS485 interface
Inverted signal (-) from RS485 interface
not assigned
SF13 and METPOINT
®
1
+ U
V
q
V
3
- U
V
5
+ I
OUT
I
2
4 ... 20 mA
Function
Plus (+) connection, power supply
Minus (-) connection, power supply
Current output
not assigned
not assigned
BDL compact (digital board)
®
BROWN
BLUE
WHITE
BLACK
Wire colour
brown
blue
white
black
grey
BDL compact (analog board)
®
BROWN
BLUE
GREY
Wire colour
brown
blue
grey
white
black
1
2
3
4
5
6
7
8
Pin assignment - BDL compact
PIN-1
+ U
V
PIN-2
- U
V
PIN-7
(+) RS485 (A)
PIN-8
(-) RS485 (B)
1
2
3
4
5
6
7
8
9
Pin assignment - BDL compact
PIN-1
+ U
V
PIN-2
- U
V
PIN-5
(+) I
METPOINT
®
EN
SF13