Installation and operating manual

5. Start-up

To start the METPOINT
FLM, power it and perform the sensor setup as described in „Sensor Setup" auf Seite 25. Slowly
®
pressurise the pipes.
6. Configuration and operation
When the METPOINT
FLM is powered, it is automatically initialised. After this step is completed, the main menu is displayed.
®
The device menus are operated through two capacitive buttons:
>>UP<<
>>ENTER<<

6.1. Display during operation

Gasart /
Statusmeldung
HW-Version
SW-Version
Press the >>UP<< button to call up pages 2 - 5.
24
Modbus ID
Seiten Nr.
CAL
indicates that calibration is due:
After 15 months, message
indicating that the device needs to be
calibrated. This message does not have
any effect on the measuring process, and
the device continues to provide accurate
measuring signals.
On request, the calibration interval can be
adjusted at the factory.
CAL
is displayed,
METPOINT
EN
SF13
®