STEP CAN ONLY BE ADDED BY PRESSING
NEXT OR THE ON/IN KEY.
10. Repeat above steps 3 to 9 to program
subsequent steps. When the sequence is
completed,
press
RUN/EXECUTE to terminate the program mode.
Note that pressing RUN/EXECUTE will store the
sequence, load it on the monitor being controlled
by the keyboard, then immediately start it
running. Pressing PROGRAM/END simply stores
the sequence for future use.
Salvo Sequence Programming
Instructions
The SalvoSwitching feature is a method of switching
video from several cameras as a synchronized group
on two or more monitors.
A practical example of the SalvoSwitching feature is
an eight story parking garage where each level has
five cameras. The system may be programmed to
enable five monitors to display the garage one floor
at a time. When in the Run mode, the system will
switch from floor to floor displaying each group for a
pre-selected dwell time.
Before
the
SalvoSwitching
programmed, it must be understood how the
Allegiant
system
executes
program. The simplest way to think of the program
information is in terms of a spreadsheet type table
consisting of steps, where each step contains four
columns of information.
The table shown below is a typical sequence used to
illustrate the SalvoSwitching feature:
Step
Cam #
1
1
2
3
3
5
4
6
5
8
6
2
7
4
8
7
9
9
10
12
The program above uses five display monitors (1-5)
to salvo switch two groups of cameras. The first
group of cameras is 1,3,5,6 and 8. The second is
2,4,7,9 and 12. The SALVO dwell command is
entered by keying in '61'. A SALVO entry indicates
that the step will be performed concurrently with the
next step. Therefore, in the above program, cameras
1,3,5,6 and 8 will be displayed on monitors 1,2,3,4
and 5, respectively, for 5 seconds before being
replaced by cameras 2,4,7,9 and 12 for 5 seconds.

Sequence Control Instructions

PROGRAM/END
or
feature
can
be
a
SalvoSwitching
Mon #
Dwell
1
SALVO
2
SALVO
3
SALVO
4
SALVO
5
5
1
SALVO
2
SALVO
3
SALVO
4
SALVO
5
5
This program will continue to sequence between
these two groups of cameras for a five second dwell
as long as the Allegiant system is in the Run mode.
If it is desired in the program to stop the display at a
particular set of salvo switched cameras, simply
replace the dwell time for that group of cameras with
the HOLD command. For example, in step 5 of the
sample sequence, replacing the dwell time of 5
seconds with the HOLD command will display
cameras 1,3,5,6 and 8 on monitors 1 through 5 until
the operator continues execution of the program by
depressing the RUN button.
As
with
any
sequence,
SalvoSwitching feature sequence may be controlled
from the keyboard with the PREVIOUS, NEXT, RUN,
and HOLD keys (see the appropriate section of the
manual). These keys treat each group of salvo
switched cameras as though they were a single step;
the cameras in the group always switch in unison.
When the sequence is running backwards, the
camera groups SALVO switch the same as when it is
running forwards.
Sequence Function Summary
All programming key functions are summarized in
the following table:
PROGRAM/END Selects or terminates program
CLEAR
ENTER
PREVIOUS
NEXT
ON/IN
OFF/OUT
UP
DOWN
LEFT
RIGHT
LOCK/DELETE
RUN/EXECUTE Exit, store, load, and run
EXAMPLE: PROGRAM 10 ENTER 1 RIGHT 1
RIGHT 2 NEXT 2 NEXT 3 NEXT 4 NEXT 5
ENTER RUN/EXECUTE
The above program (sequence #10) will sequence
cameras 1 through 5 on monitor 1 with each camera
having a dwell of 2 seconds.
51
the
operation
mode
Clears current entry
Store current entry
Store entry and move up one
step
Store entry and move down
one step; add new step if
necessary
Insert step before current step
Delete current step
Move up one step
Move down one step, if step
already exists
Move prompt left one cell
Move prompt right one cell
Erase all steps after current
step
current sequence
of
a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Allegiant ltc 8600 seriesAllegiant ltc 8800 series

Table of Contents