Test Procedures; Initial Functional Check For Fisio 120 Voice "1 Meg Version - Philips Fisio 120 VOICE Service Manual

Table of Contents

Advertisement

Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
8.0

TEST PROCEDURES

Concerning Fisio 120, it exist to memory size,:
-
one is "1 Meg" with Software 9417XXXX
-
the other size is "2 Meg" with software Product 9427XXXX
To read the software product, Insert a "SP" Card with battery in the product, Shut ON and Press *#3825*#
à Software version appeared on the LCD.
The "1Meg" version hasn't MAT (Manuel Auto Test ) inside, and to check fonctionnalities of it, you need to use an
external MAT Software Application à Refer to § 8.1
MAT software Application is available for all Fisio 120/121 Software Product.
8.1

Initial Functional Check for Fisio 120 Voice "1 Meg version"

Necessary to have MAT Software for each Software product version with Computer (Pentium 200Mhz - 64 Mo RAM)
8.1.1
Launch the MAT Software corresponding to the Product Software
8.1.2
Connect your Product (Without Sim Card) to the Data Connect cable
8.1.3
Switch ON your Phone With Key ON/OFF and Wait the below message
8.1.4
Check The "TAT MODE" on the Product LCD
8.1.5
Click on the "OK" Icon and the Product LCD will show a message which contains information of FA (Final
Adjustment) status and 12NC.
8.1.6
Follow the instructions as mentioned below :
Step
Procedure
Press Key 1
1
Press Key 1 again.
Press key 2
(Audio loop local effect)
2
Press key 2 again
Ó PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
+
Observation
Key Without test
Left corner displays 1
"LocalEffect"
" XX XX XX"
" XX XX"
Left corner displays 2
COMPANY RESTRICTED
VY-V-640-120-2
Page : 15 of 45
Language : EN
Date : 23/04/02
00
01
VY-V-640-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fisio 121 w@p

Table of Contents