Philips Fisio 120 VOICE Service Manual page 28

Table of Contents

Advertisement

Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
b) Check Current_ON
- Turn the mobile on.
When the mobile is ON (backlight activated) the current measured must be :
c) Check Current_maximum
- Press on OK to activate Page selection. Press the Key 1 and then OK to select Page 1
- Press on Key 4 to select Antenna test. Press on the left arrowhead of the Compass Key as much times as
necessary to reach level 5.
When the mobile is emitting (backlight ON) the current measured must be :
- Remove the battery.
- Gently slide the card out away from the Product
Ó PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
This measurement has to be operated during first seconds after switch on.
(The mobile is now set at his maximum emission level)
COMPANY RESTRICTED
VY-V-640-120-2
Page : 28 of 45
Language : EN
Date : 23/04/02
75 < I (mA) < 125
100 < I (mA) < 200
VY-V-640-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fisio 121 w@p

Table of Contents