Press key 0 again
Press * (IMEI Test)
Compare IMEI with label
printed on back case
11
Press * again
Press # (FA Status)
12
Press # again
Press C
Press C again
13
Press the Left arrowhead
(Melody Test) & vibrator
14
Press Left again
Press the Right arrowhead
(Memory Test)
15
Press Right again
Press "take Away" button
16
Press Green button again
Press "Hang up" button
17
Press Red button again
Ó PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
"XXXX XXXX"
Left corner displays 0
"IMEI TEST"
" XXXXXX/ 50 / XXXXXXX"
06 made in Singapore
50 made in Le-Mans
69 made in China
Left corner displays *
"FA/12NC"
FA GOOD (Must be good) X
XXXXXXXXXXX (12NC)
Left corner displays #
Handsfree
XX XX XX
XX XX
Left corner displays C
User Melody should be heard and vibrations
felt
Left corner displays 0C
"MEMORY TEST"
"XXXXXXXX"
"XXXXXXXX"
"RAM OK"
Left corner displays 0D
" MANUAL TEST"
"
GOOD
Left corner displays
" MANUAL TEST"
"
BAD
Left corner displays