Type Code; Disposal; General Information - Bosch Rextop IndraControl VCH 05.1 Operating Instructions Manual

Table of Contents

Advertisement

VCH 05.1

15.2 Type Code

Short text
column
Example: V C H 0 5 . 1 E H B - 1 2 8 E T - R 1 D - 1 2 8 - C S - E 2 - P W
Product
VCH....................... = VCH
Line
05 ...................................... = 05
Design
1..................................................... = 1
Frontplate and display
3.4", Touchscreen, with 33 keys...... = EH
3.4", Touchscreen, with 20 keys...... = EJ
Additional option
USB interface.......................................... = B
Memory capacity (RAM)
128 MB........................................................... = 128
Interface
Standard Ethernet..................................................... = ET
System configuration
OMPA 3503 ARM Cortex A8............................................... = R1
Nominal connecting voltage
24 V DC supply voltage ............................................................. = D
Compact flash size
128 MB............................................................................................... = 128
Function design
STOP-button and enabling device, three-stage, dual-circuit............................. = BS
Override, STOP-button and enabling device, three-stage, dual-circuit............. = CS
Override, handwheel, STOP-button and enabling device, three-stage, dual-circuit = DS
Override, emergency-stop button and enabling device, three-stage, dual-circuit ... = FS
Override, handwheel, emergency-stop button and enabling device,
three-stage, dual-circuit.................................................................................... = GS
Other design
Ethernet control cable, 8 m, bayonet lock.................................................................. = B1
Ethernet control cable, 0.5 m, bayonet lock............................................................... = B2
Ethernet control cable, 8 m........................................................................................ = E1
Ethernet control cable, 0.5 m..................................................................................... = E2
Ethernet control cable, 1.5 m..................................................................................... = E5
Firmware
With pre-installed firmware ................................................................................................ = PW
1)
= Function designs "FS" or "GS" are only available with Other designs "B1" or "B2"
Note:
=
Fig. 15-1: Type code for VCH 05.1

16 Disposal

16.1 General Information

Dispose of the products according to the respective national standard.
DOK-SUPPL*-VCH*05*****-IT02-EN-P
1 2 3 4 5 6 7 8 9
1)
Function designs "DS" or "GS" are only available with Front plate and display "EJ"
1
2
0 1 2 3 4 5 6 7 8 9
0 1 2 3 4 5 6 7 8 9
Bosch Rexroth AG
Disposal
3
0 1 2 3
21/27