Lift Number

This BFM contains the lift number to which the FX
The Bit for the assigned lift number is set to ON (1).
Note
Only the application BFMs for which the Lift corresponding bit is set will be updated.
Data save to Flash ROM
Data can be saved in Flash ROM by CIF.
BFM No.
BFM #3000
BFM #13000
8.3

Virtual Input/Output Mapping

When BFM #3001 to #3003 and #12001 to #12003 are read, the virtual input mapping information is read
from BFMs. When BFM #13001 to #13003 are read, the virtual output mapping information is read from
BFMs. And when BFM #3001 to #3003 and #13001 to #13003 are written to, the virtual output mapping
information is written to BFMs.
8.3.1

Virtual input mapping

These BFMs contain the last received input data from one of the digital input panel group objects.
Receive Ring Buffer for 252 messages. The oldest data will be shown as first.
The current numbers of messages in the receive Buffer can be read from BFM #3004 or #12004.
When the receive buffer is empty, BFM #3001 to #3003 or #12001 to #12003 shows the value H0.
BFM No.
BFM #3001 to #3003
BFM #12001 to #12003
1. Basic function field [Low byte in BFM #3001 and #12001]
BFM #3001
BFM #12001
Low Byte
Value (hex)
00
Reserved
01
Generic input
02
Standard hall call request
03
Low priority hall call request
04
High priority hall call request
05
Standard car call request
06
Low priority car call request
07
High priority car call request
08
Standard destination call
09
Low priority destination call
0A
High priority destination call
0B
Standard call to destination floor
0C
Low priority call to destination floor
152
→ For Store Object Dictionary Settings in the CIF, refer to Section 10.6
Bit 15
.....
Bit 8
Reserved
BFM #3003
BFM #12003
High Byte
Low Byte
Function data field
Door field
Description
-CAN is assigned.
3U
Description
Bit 7
Bit 6
Bit 5
Lift 8
Lift 7
Lift 6
Description
BFM #3002
BFM #12002
High Byte
Low Byte
Floor field
BFM #3001
BFM #12001
Low Byte
Value (hex)
0D
High priority call to destination floor
0E
Special function
0F
Access code upload request
10
Speech connection request
11
Area monitoring connection request
12
Fire detector
13 to 15
Reserved
Status of safety-related circuitries
16
(This is not safety-related information.)
17 to 1F
Reserved
20
Guest call
21 to 7F
Reserved
80 to FF
Manufacturer-specific
8 CANopen
Bit 4
Bit 3
Bit 2
Lift 5
Lift 4
Lift 3
BFM #3001
BFM #12001
High Byte
Lift field
Sub-function field
Description
®
417 Mode
8.2 Lift Number
Bit 1
Bit 0
Lift 2
Lift 1
Low Byte
Basic function field