Beko BEKOKAT CC-1200 Installation And Operation Manual page 39

Catalytic converter for removing oil from compressed air, version 11 bar
Table of Contents

Advertisement

1) At inlet temperatures above + 45 °C, temperatures> + 60 °C may occur at the outlet of
the BEKOKAT
components.
Technical data BEKOKAT
Maximum
permissible
pressure PS
Permissible minimum/maximum
operating temperature TS
Test pressure (hydraulic) PT
Pressure vessel volume V
Pressure
equipment
according to PED
Load alternation
Design and construction
Identification marking
V01 / 11-043
®
. Please pay attention to the corresponding design of the following
®
operating
11 bar (g)
-10°C / +300°C
33.3 bar(g)
200.0 litres
category
III
1,000 arrivals and departures
According to PED 2014/68/EU and AD-2000
Refer to rating plate
Installation and Operation Manual BEKOKAT
®
39 / 88

Advertisement

Table of Contents
loading

Table of Contents