Layering in GX LogViewer
Display the workpiece height in a waveform in GX LogViewer to check.
Operating procedure
1.
Display the failed product detection threshold and workpiece height real number in waveforms in GX LogViewer.
Select a device/label Right-click [Wave Display]
2.
Layer the waveforms of the failed product detection threshold and workpiece height real number.
3.
It is determined that one workpiece was judged as a failed product since its height was higher than the threshold, and the
error occurred.
Waveform of the workpiece
height real number
7 OPERATION EXAMPLE
7.1 How to Check the Recording Result
7
72