Vibration Sensor; Auto Detection; Adjusting Sensor Sensitivity Setting - Hitachi EP-A9000 Instruction Manual

Air purifier with humidifying function
Table of Contents

Advertisement

Vibration Sensor

 The sensor detects a fall and impact on the unit. (Installed inside the unit)
 The operation may stop due to tilting of the unit, strong vibrations or impact of a collision.
When the operation stops, "

Auto Detection

 The air purifi er performs automatic operation by detecting room air contamination using the "Odor Sensor" and "Dust
Sensor", and room air temperature and humidity using the "Temperature / Humidity Sensor".
During the fi rst 3 minutes after the power is turned on, the unit will check the air condition of the room.
 The purifi er operates even while it checks the air condition of the room.
During this time, the "Air Sensor" fl ashes green.
 After checking the air condition, the "Air Sensor" will display the room air contamination using the "Odor Sensor"
and the "Dust Sensor".
 If you plug in the power cord in an environment containing contaminated air, the sensitivity of the sensor may be
reduced.
To clean the air of the room, operate in "High" or "Max". Or open a window and unplug the power cord from the AC
outlet when ambient air is clean and plug it back in after 10 minutes.
Adjusting Sensory Sensitivity Setting
 Sensitivity of the "Odor Sensor" and "Dust Sensor" which performs automatic switching of airfl ow rate can be ad-
justed in 3-step fashion.
You can adjust the sensor sensitivity setting as desired.
 The "Odor Sensor" and "Dust Sensor" are similarly adjusted.
Display
Sensor
Low
Sensitivity
1
While pressing
The current sensitivity is indicated and displayed. (Factory setting is
2
While the sensitivity is being displayed (about 10 seconds),
continue long-pressing
The sensitivity display will change from
3
Furthermore, when switching sensitivity, repeat procedure
When repeating, the sensitivity display will switch like this
About 10 seconds after the sensitivity display has been switched, it will disappear and the selected sensor sensitivity will be set.
Note
 Switching the sensitivity of the sensor does not correspond to the "PM2.5 Sensor" cycle.
" is displayed on the temperature / humidity monitor and the unit can no longer operate.
High
Medium
, long-press
Display
for about 3 seconds, while pressing
Air
flow
Air Purify
Display
Timer
·
·
·
Lock
Dimmer
Maintenance
Type 1/2/Off
Reset
1
Air
for about 3 seconds
flow
)
.
(P.E-39)
Auto
Air
PM2.5
Mode
Option
flow
Sensor
2
once more.
Display
.
2
... .
(P.E-24)
E-27