  • Page 1 CASSETTE TYPE AIR CONDITIONER Operation & Installation Manual AB072XCEAA AB092XCEAA AB122XCEAA AB142XCEAA No. 0010577688 Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely. http://splitoff.ru/tehn-doc.html...
  • Page 2: Table Of Contents

    Contents Cautions ..................... Main Points of Operation ..............Part Name ................... Safety Precautions ................Maintenance ..................When Trouble Happens ..............Customer Need-to-know ..............Installation Tools ................Installation Procedures ..............13-19 Troubleshooting ................20-21 Failure code ..................Check and Test Run ................: http://splitoff.ru/tehn-doc.html...
  • Page 3: Cautions

    Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner Before starting the air conditioner, read the that goes out of use, please make sure it's information given in the User's Guide inoperative and safe. Unplug the air carefully.
  • Page 4 Cautions Do not obstruct or cover the ventilation 5. The power cord should be self-provided and grille of the air conditioner. Do not put it should have got the Local authentication fingers or any other things into the certificate. inlet/outlet and swing louver. 6.
  • Page 5: Main Points Of Operation

    Main Points of Operation Operation of Air Conditioner When the environmental humidity is heavy, water will be dripped from the air outlet in cooling or drying mode. 3-minute Protection Function If restarting the unit immediately after unit stops, the compressor will start only 3 minutes later to protect the machine.
  • Page 6 Main Points of Operation Anti-cold Blowing Off Wait a minute In heating mode,the indoor fan will not run immediately after the unit starts up, which will the cold air being blow out. Defrosting Function In heating mode, when frost is formed on the outdoor heat exchanger, the air conditioner will automatically defrost for few minutes.
  • Page 7: Part Name

    Part Name Indoor unit Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller) Operating Control Panel Air Inlet Grille Air Filter (Inside of the Inlet Grille) Operating Control Panel Remote receiver Compressor Lamp TIMER Lamp OPERATION Lamp COMP TIMER OPER POWER...
  • Page 8: Safety Precautions

    Safety Precautions Carefully read the following information in order to operate the air conditioner correctly. Below are listed four kinds of Safety Precautions and Suggestions: WARNING: Incorrect operations may result in severe consequences of death or serious injures. Incorrect operations may result in injures or machine damages; in some cases may CAUTION : cause serious consequences.
  • Page 9 Safety Precautions WARNING No goods or nobody is permitted Don’t clean air conditioner with water. to be placed on or stand on Otherwise may cause shock. outdoor unit. The falling of goods and people may cause accidents. Don't operate the air conditioner with damp hands.
  • Page 10: Maintenance

    Maintenance Clean the unit Turn off the power supply switch Do not use hot water or volatile liquid Do not touch with wet hand. Fixing nolt press the locks Take down air inlet grille As the figure, press the two locks on air inlet grille vertically, and make it move to grille, then rise it up 45 degree gently to take out the grille.
  • Page 11 Maintenance Seasonal Reserve Post-season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in state. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
  • Page 12: When Trouble Happens

    When Trouble Happens Insufficient cooling or heating The operation controller Air filter too dirty ? Horizontal swing louver adjusted as required upward ? (in HEAT mode) Any obstacle exists at the air Door or window left open ? inlet or outlet? Insufficient cooling Too crowed in the room ? Sunlight direct into the...
  • Page 13: Customer Need-To-Know

    Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner works well. Be careful not to scratch the surface of the case when moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place.
  • Page 14: Installation Tools

    Installation Tools Installation tools The installation tools listed in the following sheet can be used as required. 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7.
  • Page 15: Installation Procedures

    Installation Procedures 1.Selection of Installation Place (1) Place above the ceiling where it is enough space to arrange the unit. (2) Place where the drainage pipe can be arranged well. (3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop).
  • Page 16 Installation Procedures (3) Install a suspending bolt To support the unit weight ,anchor bolt should be used in the case of the existing ceiling. For new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field. Before going on installing, adjust the distance to ceiling.
  • Page 17 Installation Procedures 4. Installation of water drainage pipe (1) Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm ) Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slope of drainpipe cannot be made,lifting pipe shall be installed.
  • Page 18 Installation Procedures 6. Installation of Ornament Panel Install ornament panel on indoor unit (1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before installing the ornament panel.
  • Page 19 Installation Procedures (1) Dimension of connecting pipe AB072XCEAA Gas pipe 9.52mm AB092XCEAA AB122XCEAA Liquid pipe 6.35mm AB142XCEAA Fit the nut on and fasten (2).Pipe cutting and expanding Must remove burrs if cut pipes with pipe cutter. Expand flare after insert the pipe expander.
  • Page 20 Installation Procedures (4) Purging method ( the refrigerant is R410A) Liquid pipe To use vacuum pump Gas pipe 2-way valve Detach the service port's cap of 3-way valve, the 3-way valve valve rod's cap for 2-way valve and 3-way's, connect Gaugemanifold (R410A) the service port into the projection of charge hose (low) for gauge manifold.
  • Page 21 Installation Procedures Electrical Wiring Cautions: Use copper wire only.Parameters of connecting line : H05RN-F 3G(1.0~1.5)mm +H05RN-F 2x(0.75~1.5)mm Power supply :1PH,220-230V~,50Hz. Power supply wire parameters: H05RN-f 3G(0.75~1.5)mm Signal wire parameters: H05RN-F 2x0.75mm The signal wire must be shielded wire. Wiring methods: 1.Wiring method of ring terminal Wiring method of ring terminal For connecting line which end is a ring,its wiring method...
  • Page 22: Troubleshooting

    Troubleshooting The followings are not malfuncition When the air conditoner is started, when the Water flowing sound is heard compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds “ Bi- Bi-” or “Godo-Godo”. It is the flowing sound of the refrigerant , not a malfunction.
  • Page 23 Troubleshooting Air does not blow or the fan speed cannot be In DRY mode, when room temperature changed during drying. becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting This happens when the frost accumulated on Water or vapor generated from the outdoor the outdoor unit is removed (during defrosting unit during heating.
  • Page 24: Failure Code

    Failure code : http://splitoff.ru/tehn-doc.html...
  • Page 25: Check And Test Run

    Check and Test Run Installation check and test run Require customers to use air conditioner according to the operation manual. The items checked during test run,please mark No gas leakage on the pipe joint ? How about the thermal insulation of the pipe joint: Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly? Is the wiring of indoor and outdoor unit secured firmly? Is the drainage hose arranged correct?
  • Page 26 HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P.R.China Web Site: http://www.haier.com http://splitoff.ru/tehn-doc.html...