Trouble Shooting - Sharp SWD-78EHL-SL Service Manual

Hot & cold hidden bottle water cooler
Table of Contents

Advertisement

11. Trouble shooting

Problems
1. Switch doesn't work (Or switched off on LCD panel)
2. Fuse(s) burnt
Hot water is not hot
3. Control board and NTC sensors don't work
4. Heater doesn't work
5. Wires are disconnected
1.Switch doesn't work (Or switched off on LCD panel)
2.Fuse burnt
3.Control board and NTC sensor don't work
Cold water is not
4.Compressor doesn't work
cold (<10C)
5.Refrigeration sys leaks
6.Wires are disconnected
1.Bottle probe leaks
No water come out
2.Air pump doesn't work
from the taps
3.Control board doesn't work
4.Float switch and float assembly have problem
Tap flow is too slow
1.Water level is too low in the water reservoir
(<1.5L/min)
2.Silicone tube is twisted
1.60 DbA in 2-3 minutes is normal when water starts boiling
Heating noise
2.Voltage is too high
1.Voltage and frequency are unstable
Cooling noise
2.Condenser or internal parts are not well installed result
resonance
1.Installation is not good
Pump noise
2.Probe assembly results bigger noise sometimes
1.Source water may has taste or out of date
Water has taste
2.Cooler may not be cleaned when first time use or long time
use
1.Probe or tube leak
2.Door switch or float switch failure
Pump doesn't work
3.Transformer or Control board don't work
4.Wire connection failure
5.Air pump doesn't work
Water pump work
1.Wrong wire connection
continuously
2.Control board doesn't work
Door gap is too big
Door hinge plate distort
Door gap is not
Diagonal distort
even
Door can't be closed
1.Door distort diagonally or the folding edge distort obtusely
tightly
2.Door folding edge distort
Trouble shooting
Reasons
How to solve
1. Check switch (Turn on by touching LCD key)
2. Check fuse(s)
3. Check heater
4. Check control board and NTC
5. Check wiring
1.Check switch (Turn on by touching LCD key)
2.Check fuse
3.Check control board and NTC
4.Check compressor
5.Check the temperature of condenser, hot
means refrigeration sys works
6.Check wiring
1. Check O rings of the stick, reinstall the probe
assembly
2. Check air pump and it's wire connection
3. Check control board
4. Check float switch and float assembly
1.Check float assembly, check baffle plate
inside the water reservoir
2.Check silicone tube
1.Use dbmeter check if it is too high
2.Check voltage is 220V or not.
1.Check voltage and frequency
2.Hold the condenser by hand, if the noise
disappear, then put rubber pad between
condenser and side panel
1.Check the installation, especially the soft
sleeve
2.Take apart the probe assembly to see if it is
normal, then change a new one.
1.Change new bottled water and clean the
cooler.
2.Flush the cooler for a few times with boiling
treatment according to the taste treatment
instruction.
1.Check the probe and O rings, then reinstall
2.Check door switch and float switch
3.Check transformer(Check if the LED light
work) and control board
4.Check wire connection
1.Check wire connection
2.Change control board
Change hinge plate or add washer above the
hinge shaft
Rectify the corner diagonally according to the
instruction of "How to fix the door gap"
1.Rectify the door by hand
2.Rectify the edge by hand
page 11
Notice

Advertisement

Table of Contents
loading

Table of Contents