3 Installing RRU and SRXU Hardware
l
l
Space Requirements of Multiple RRUs with and Without the SRXUs
Figure 3-10
the SRXUs.
Figure 3-10 Recommended space requirements of multiple RRUs with and without the SRXUs
(unit: mm)
The recommended space around the equipment is as follows:
l
l
l
l
l
l
l
Figure 3-11
SRXUs.
3-10
When two RRUs are installed horizontally, the space is 1,200 mm at most.
When two RRUs are installed vertically, the space is 800 mm at most.
NOTE
The space requirements of two combined SRXUs are the same as those of two combined RRUs.
shows the recommended space requirements of multiple RRUs with and without
At least 500 mm under the equipment for cabling. It is recommended that the space is 1,200
mm between the bottom and the ground for easy maintenance.
At least 800 mm in front of the equipment for maintenance.
At least 200 mm above the equipment for maintenance.
At least 800 mm on the left of the equipment for maintenance.
At least 800 mm on the right of the equipment for maintenance.
Regardless of whether the SRXUs are fixed to the RRU, the space requirements are the
same.
Regardless of whether the RRUs are in two-module or three-module centralized installation
mode, the space requirements are the same.
shows the minimal space requirements of multiple RRUs with and without the
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
RRU
User Guide
Issue 01 (2008-04-18)