Scanner Unit Removal - Epson Stylus PHOTO RX600 Service Manual

Hide thumbs Also See for Stylus PHOTO RX600:
Table of Contents

Advertisement

EPSON Stylus PHOTO RX600/610, RX620/630

4.2.2 Scanner Unit Removal

1.
Panel Unit Removal. (p41)
2.
Remove one screw that secures the FFC cover.
3.
Remove the FFC cover from the middle housing.
4.
Remove a TPU cable and a Grounding cable from the printer unit.
5.
Remove all main board connectors.
6.
Remove ferrite core from the middle housing.
7.
Remove two hinge screws that secure the middle housing.
8.
Remove the scanner unit upward easily.
Disassembly and Assembly
C.B.P.Tite 3x8,F/ZN
Tightening torque:0.6 ± 0.1 N
Scanner Unit
C.B.P Tite 3x8,F/ZN
Tightening torque
:0.6 ± 0.1 N
m
Scanner FFC
Ferrite Core
Main Unit Removal
m
FFC Cover
Grounding cable
Figure 4-2. Scanner Unit Removal