Disassembly And Assembly Of Panel Unit; Panel Circuit Board Removal - Epson Stylus PHOTO RX600 Service Manual

Hide thumbs Also See for Stylus PHOTO RX600:
Table of Contents

Advertisement

EPSON Stylus PHOTO RX600/610, RX620/630

4.3 Disassembly and Assembly of Panel Unit

4.3.1 Panel Circuit Board Removal

1.
Panel Unit Removal. (p41)
2.
Remove one screw that secures the grounding plate.
3.
Remove the grounding plate from the panel shield plate.
4.
Remove six screws that secure the shield plate.
5.
Remove the panel shield plate from the front middle cover.
6.
Disconnect a harness from the panel circuit board.
7.
Remove six hooks that secure the panel circuit board.
8.
Remove the panel circuit board from the middle cover.
Do not touch the switch contacts on the panel circuit board with
C A U T I O N
bare hand; otherwise, contact error can occur.
Disassembly and Assembly
Disassembly and Assembly of Panel Unit
Front Middle Cover
Panel Circuit Board
Panel Shield Plate
C.B.P Tite 3x8,F/ZN
Tightening torque:0.6 ± 0.1 N
m
Grounding Plate
C.B.P Tite 3x8,F/ZN
Tightening torque:0.6 ± 0.1 N
Figure 4-4. Panel Circuit Board Removal
Revision C
Panel Harness
m