Error Code - Mitsubishi Electric MELSEC iQ-R Series User Manual

Camera recording package
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error code

Error code
Description
C1E0H
• Effective range error (Connection No./User name/Password)
The set data is out of effective range: iw_ConnectionNo is not set within
1 to 16; is_UserName is not set within 4 to 14 characters; or
is_PassWord is not set within 4 to 64 characters.
C1E2H
• Timeout error
No response is returned from the network camera after the command is
sent.
C1E3H
• User name/password setting error
Unregistered is_UserName or is_PassWord is set.
Other than the
Errors that occur in each processing for data communication between
above
the Ethernet-equipped module and external device, and errors that
occur in processing requests from the CPU module in the own station
10 FB LIBRARY DETAILS (FOR MELSEC-Q SERIES CPU MODULES)
96
10.1 M+CPU-CamRec_AXIS_SetTime
Action
Review and correct the input label, and execute the FB again.
Review and correct the following, and execute the FB again.
• When the constant scan time exceeding 500ms is set, set it
to 500ms or less, or leave it blank.
• Check that recording events are not overlapped due to
consecutive recording triggers that occur in a brief period of
time.
After performing the following, execute the FB again.
• Review and correct the input label.
• There may be no response from the network camera.
Restart the programmable controller and the network
camera.
 QCPU User's Manual (Hardware Design, Maintenance
and Inspection)