2) TSTP (Timer STOP) bit
This bit controls the temporarily stopped of Timer Counter.
TSTP
Data
0
Write/Read
1
3)
TRES (Timer Reset) bit
This bit can be employed like Watch Dog Timer function.
TRES
Data
0
Write/Read
1
4) TE (Timer Enable) bit
This bit controls the start/stop setting for the fixed-cycle timer interrupt function.
TE
Data
0
Write/Read
1
5) TF (Timer Flag) bit
If set to 0 beforehand, this flag bit's value changes from "0" to "1" when a fixed-cycle timer interrupt event has
occurred. Once this flag bit's value is "1", its value is retained until a "0" is written to it.
TF
Data
0
Write
1
0
Read
1
6) TIE (Timer Interrupt Enable) bit
When a fixed-cycle timer interrupt event occurs (when the TF bit value changes from "0" to "1"), this bit's value
specifies whether an interrupt signal is generated (/INT status changes from Hi-Z to low) or is not generated (/INT
status remains Hi-Z).
TIE
Data
0
Write/Read
1
Timer Counter are stopped.
Count down of the Timer Counter are continued.
The Timer Counter is not affected.
Preset value are loaded to all Timer Counters.
Preset value loaded to all Timer counter, and count-down stops.
Starts fixed-cycle timer countdown.
The countdown that starts when the TE bit value changes from 0to 1 always begins from the preset
value.
The TF bit is cleared to zero to prepare for the next status detection
Clearing this bit to zero does not enable the /INT low output status to be cleared (to Hi-Z).
Invalid (writing a 1 will be ignored)!
Fixed-cycle timer interrupt events are not detected.
Fixed-cycle timer interrupt events are detected.
(Result is retained until this bit is cleared to zero.)
1) When a fixed-cycle timer interrupt event occurs, an interrupt signal is not
generated or is canceled (/INT status remains Hi-Z).
2) When a fixed-cycle timer interrupt event occurs, the interrupt signal is
canceled (/INT status changes from low to Hi-Z).

Even when the TIE bit value is "0" another interrupt event may change the /INT status to low (or may
hold /INT =L).
When a fixed-cycle timer interrupt event occurs, an interrupt signal is generated
(/INT status changes from Hi-Z to low).

When a fixed-cycle timer interrupt event has been generated low-level output from the /INT pin
occurs only when the value of the control register's TIE bit is 1. Earliest 7.813 ms the interrupt occurs,
the /INT status is automatically cleared (/INT status changes from low to Hi-Z).
Page - 17
Description
(don't reset.)
Description
Description
Description
Description
ETM60E-02