Every 2000 Hours Maintenance; Method For Checking Fan Belt Tension And Replacing Fan Belt; Method For Checking Alternator Belt Tension And Replacing Alternator Belt; Method For Changing Oil In Final Drive Case - Komatsu PC360NLC-11 Operation & Maintenance Manual

Hydraulic excavator
Table of Contents

Advertisement

MAINTENANCE
NOTICE
If breather assembly (1) is removed for replacement, apply a tool to bolt (5) and tighten it.
Tightening torque: 6.5 to 8.5 Nm{0.66 to 0.87 kgm}
5.
Close DEF tank cover at the right of the machine.

METHOD FOR CHECKING FAN BELT TENSION AND REPLACING FAN BELT

Special tools are required for the inspection and replacement.
Ask your Komatsu distributor to perform this work.
REMARK
As the automatic fan belt tensioner is installed to this machine, no belt tension adjustment is required.
METHOD FOR CHECKING ALTERNATOR BELT TENSION AND REPLACING AL-
TERNATOR BELT
Special tools are required for the inspection and replacement.
Ask your Komatsu distributor to perform this work.
REMARK
As the auto alternator belt tensioner is installed to this machine, no belt tension adjustment is required.

EVERY 2000 HOURS MAINTENANCE

Maintenance for every 50, 250, 500 and 1000 hours service should be performed at the same time.

METHOD FOR CHANGING OIL IN FINAL DRIVE CASE

Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury. Accordingly, wait until they have cooled down before starting the work.
If there is remaining pressure inside the case, the oil or plug may jump out. Loosen the plug slowly
to release the pressure.
Do not stand in front of the plug when you loosen the plug.
Refill capacity (each of right and left):9.0 ℓ
Items to be prepared
Container to receive drained oil
Handle
k
k
WARNING
MAINTENANCE PROCEDURE
4-65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc360lc-11

Table of Contents