Smart Energy Plug PAN44
This plug-in ON/OFF switch PAN44 is a devices displaying the Z-Wave Plus
also be used security enabled wireless switch, based on Z-Wave Plus technology. Z-
Wave Plus
TM
enabled with it regardless of the manufacturer, and can also be used in
other manufacturer's Z-Wave
TM
enabled networks. Remote On/Off control of the con-
nected load is possible with another manufacturer's wireless Controller. Each switch is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal around obstacles and
radio dead spots. Because PAN44 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes are identical when
included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (1560W/UL/TW/JP) and
overload current (14.5A with resistive load) of connected lights or appliances. When de-
tecting overload state, the Switch will be disabled and it's On/Off button will be lockout
of which LED will flash quickly. However, unplug and reconnect the switch will reset its
overload condition to normal status.
Specification
Operating Voltage
Maximum Load (Ampere)
Range
Operating Temperature
Frequency Range
RF Maximum Power
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
TM
logo can
The Switch not working
and LED off
The Switch LED illumi-
nating, but cannot control
the Switch of the load at-
tached
The Switch LED illumi-
nating, but the Detector
cannot control the Switch
LED keep flashing, but
cannot control
100V-240V~ 50Hz~60Hz
13A (Resistive load) PAN44-1; PAN44-2
Minimum 40 m in door 100m outdoor line of sight
0°C ~ 40°C
908.4MHz & 916.0MHz/ USA (PAN44-1);
920~927MHz/ Taiwan/ Japan (PAN44-2)
+10dBm (Peak), -10dBm (Average)
Cause of Failure
1.The Switch is not plugged into
1. Check power connections
the electrical outlet properly
2. Don't open up the Switch
2.The Switch break down
and send it for repair.
1. Set the ON/OFF switch of
1.Check if the load plugged into
the load attached to ON
the Switch has its own ON/OFF
2. Unprotected the switch or
switch
follow the instruction of pro-
2. The switch is protected
tection.
1. Not carry out association
1. Carry out association
2. Same frequency interference
2. Wait for a while to retry
Remove the load attached or
Overload occurs
check max. load cannot ex-
ceed 13A (Resistive load)
Recommendation

Advertisement

loading

Summary of Contents for Philips PAN44

  • Page 1 Switch of the load at- switch follow the instruction of pro- radio dead spots. Because PAN44 supports Security Command Class, it can learn with tached 2. The switch is protected tection.
  • Page 2 For Instruction to http://www.philio-tech.com Adding to Z-Wave Network In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carries out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2 second intervals.
  • Page 3: Led Indication

    DSK: 18112-24021-58001-62259- at any time. Or If your controller re- 57092- 27453-08187-47408 quires to have the PAN44 send a 2.PAN44 is supported with Smart- node information frame or NIF for Start, it can be added to Z-Wave™...
  • Page 4: Installation

    On/Off button, it will stop flashing temporarily. 1-1 BASIC_GET / BINARY_SWITCH_GET Learning When PAN44 is in learning mode, LED flashes on and off alternately and Upon receipt of the following commands from a Z-Wave Controller, the repeatedly at 0.5 second intervals.
  • Page 5 When receiving Meter Get Command, it will report Meter Report Command to 2-1-3 Overload alarm report the node. When PAN44 detects the current is more than 14.5A, it will send Alarm Report to Group 1 node. Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KWh)]...
  • Page 6 Example: Meter Value 2 = 0x01(V) Scale = 0x00 (KWh) AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V) Precision = 2 Size = 4 Bytes (KWh) 2-2-5 AC load current ( I ) Meter Value 1 = 0x00(KWh) When receiving Meter Get Command, it will report Meter Report Command to Meter Value 2 = 0x01(KWh) the node.
  • Page 7 10min 1~32767: 3-2 KWH Meter Report Period: 0x7FFF If the setting is configured for 1hour (set value =6), PAN44 will report its Ac- 10min~ 227days cumulated Power Consumption (KWh) to Group1 node every 1 hour. The Threshold of 10-1300 0.01A 1300 1300*0.01A...
  • Page 8 3-8 Watt differential mode:The default setting is 1 (= 5%). Configuration Highest granted Security Class Whenever Watt value of PAN44 changes over 5% of last reading value, it will Device Reset Locally Highest granted Security Class send Meter report to the group 1 nodes. However, if Watt differential mode as 0, the unsolicited report will be disabled.
  • Page 9 Note: Please make sure that the intensity of the plug of the electrical device must aged to try to correct the interference by one of the following measures: be 16A and have same head as the enclosed plug before inserting to the socket. •...