Cleaning the Nozzle Guides
Check and remove any grass, dirt or debris buildup
around and in between the nozzle guides
Keep the nozzle free of debris to prevent the motor
from stalling.
Figure 27
1. Nozzle guides
Adjusting the Nozzle Belt
Service Interval: After the first 8 hours
(Figure
27).
Every 50 hours
Adjust the belt if the belt slips when changing direction
of the nozzle.
1.
Press the belt, at the center of the longest span,
with 30 N∙m (22 lb) of force
Note:
inch).
2.
If the deflection is incorrect, proceed to the next
step. If it is correct, continue operation.
g362316
1. Flange nut
2. Hex nut
3.
Loosen the hex nut and tighten the flange nut to
increase the belt tension
Note:
4.
Tighten the hex nut to lock the adjustment.
18
(Figure
The belt should deflect 4.8 mm (0.19
Figure 28
3. Depress belt here
(Figure
Do not over tighten.
28).
g021636
28).